L.P. Gas Flowmeter
Type 4D-MD
1"

OPERATING SPECIFICATIONS
Flow Rate
Maximum
Minimum
LPM
68
11
US Gal./Min
18
3
Operating Pressure
Maximum
Minimum
Bars
24
See Note
PSI
350
See Note
Operating Temperature
Maximum
Minimum
ºC
60
-23
ºF
140
-10
Temperature Compensation
Compensates to a basepoint of 15 ºC (60 ºF)
Range: -23 to 52 ºC (-10 to 125 ºF) 
Connections
Ductile iron companion flange tapped for 3/4" std. pipe
Optional steel companion flange tapped for 1" std. pipe 
Note: A minimum of 1.034 bars (15 psi) is needed to open the differential control valve, plus pressure loss in the system.